Model NO.: GC5891N
Trademark: Haida
Transport Package: Strong Wooden Case
Origin: Guangdong, China
Model NO.: GC5891N
Trademark: Haida
Transport Package: Strong Wooden Case
Origin: Guangdong, China
High-End Lab Gas Chromatography Instrument With Automatic Sampler
Description:
The entire new generation of laboratory high-end automatic gas chromatograph gc6891n, the basic international most advanced technology platform and decades of international industry technology application experience, function, reliability and application flexibility, etc. in the industry leader.
Application:
Oil extraction and refining, petrochemical, fine chemicals, food safety, environmental protection, electronic high purity gas industry, research institutes, quality inspection, safety supervision, police forensic and national security and other fields of analysis and detection.
Performance:
1.Inlet flow rate, chromatographic column load flow, detector gas flow, complete EPC control
Micro-channel Air Circuit Integrated Board
All-imported miniature proportional valves and flow/pressure sensors
Automatic temperature compensation ensures accurate flow and pressure control to 0.01Psi
2.Industry-Leading Detector design
All detectors are high-precision electronic flow/pressure control
Fit and fill column and capillary column
Special ceramic treatment of the enlarged plate, in the humid season is always stable
3.Automatic ignition, hydrogen leak automatic protection function, safe and reliable
4.Accurate furnace temperature tracking design
5.Independent Heating small column box
In the multi-column chromatographic system, the temperature of different columns can be set respectively, so as to achieve the best separation effect of each column.
6.Fully Imported Valve configuration system
Up to 8 valves (four-pass valve, six-pass valve, ten-pass valve and liquid injection valve optional); Automatic control, sequence operation;
7.Precise temperature control of the programmed furnace
Furnace internal control accuracy less than 0.01°c
The temperature difference between the internal points is not more than the °c
Rapid heating and cooling, the highest program heating speed: 120ºC/min, balance time 10 seconds, cooling time 300°c~50°c 6 minutes
Absolute control of the temperature accuracy (with the actual temperature difference is less than 0.3C)
8.The convenient realization of gas cutting technology
Multi-dimensional chromatographic function to complete the separation and analysis of complex samples
It can realize the inverse blowing function of chromatographic column to save the analysis time and cycle greatly.
9.Advanced Power Distribution Management shunt
A 3000 watt UPS can provide 10 units of normal power 2250 watts/set of GC stable working power supply automatic Feed
10.Automatic injection
8-bit automatic injection device (optional Agilent 7683/7693 liquid automatic injection)
11.Automatic Online inspection function
Parameter:
(The table parameters for the company Standard Model parameters, we support customer customization parameters)
(The table parameters for the company Standard Model parameters, we support customer customization parameters)
The introduction of Haida
Haida products are widely used in paper products, packaging, ink printing, adhesive tapes, bags, footwear, leather products, environment, toys, baby products, hardware, electronic products, plastic products, rubber products and other industries, and are applicable to all scientific research units, quality inspection institutions and academic fields. Our products meet UL, ASTM, JIS, GB,SO, TAPPI, EN, DIN, BS and other domestic and international standards.
Â
Packaging & Shipping:
Simulation Animatronic Customer Triceratops are covered with air bubble film before put them into the wooden case, which not only has good shock absorption, impact resistance, heat sealing and also has the advantages of nontoxic, odorless, moisture corrosion, good transparency etc.
Â
After-service:
If you face any problems in future during testing process we promise we will give you a reply within 48 hours and solution provide within 3 working days. We can offer operation video and English operation muanual. We can provide video-con.
Â
The entire new generation of laboratory high-end automatic gas chromatograph gc6891n, the basic international most advanced technology platform and decades of international industry technology application experience, function, reliability and application flexibility, etc. in the industry leader.
Application:
Oil extraction and refining, petrochemical, fine chemicals, food safety, environmental protection, electronic high purity gas industry, research institutes, quality inspection, safety supervision, police forensic and national security and other fields of analysis and detection.
Performance:
1.Inlet flow rate, chromatographic column load flow, detector gas flow, complete EPC control
Micro-channel Air Circuit Integrated Board
All-imported miniature proportional valves and flow/pressure sensors
Automatic temperature compensation ensures accurate flow and pressure control to 0.01Psi
2.Industry-Leading Detector design
All detectors are high-precision electronic flow/pressure control
Fit and fill column and capillary column
Special ceramic treatment of the enlarged plate, in the humid season is always stable
3.Automatic ignition, hydrogen leak automatic protection function, safe and reliable
4.Accurate furnace temperature tracking design
5.Independent Heating small column box
In the multi-column chromatographic system, the temperature of different columns can be set respectively, so as to achieve the best separation effect of each column.
6.Fully Imported Valve configuration system
Up to 8 valves (four-pass valve, six-pass valve, ten-pass valve and liquid injection valve optional); Automatic control, sequence operation;
7.Precise temperature control of the programmed furnace
Furnace internal control accuracy less than 0.01°c
The temperature difference between the internal points is not more than the °c
Rapid heating and cooling, the highest program heating speed: 120ºC/min, balance time 10 seconds, cooling time 300°c~50°c 6 minutes
Absolute control of the temperature accuracy (with the actual temperature difference is less than 0.3C)
8.The convenient realization of gas cutting technology
Multi-dimensional chromatographic function to complete the separation and analysis of complex samples
It can realize the inverse blowing function of chromatographic column to save the analysis time and cycle greatly.
9.Advanced Power Distribution Management shunt
A 3000 watt UPS can provide 10 units of normal power 2250 watts/set of GC stable working power supply automatic Feed
10.Automatic injection
8-bit automatic injection device (optional Agilent 7683/7693 liquid automatic injection)
11.Automatic Online inspection function
Parameter:
(The table parameters for the company Standard Model parameters, we support customer customization parameters)
Column temperature Box | |
Furnace Size | 28×30×18cm |
Temperature control Range | higher than room temperature 5ºC~450ºC; Use liquid nitrogen cold well -80ºC~400ºC; use dry ice trap -55ºC~400ºC |
Temperature setting accuracy | 0.1ºC |
Maximum program heating rate | 120ºC/min |
Maximum once method run time | 999.99min |
Maximum class of program heating | 7 class |
Programmed Temperature Rate | 0.1~120ºC/min (increment 0.1 ºC) |
Operation Column loss compensation (dual channel) | |
Heating Zone | |
6 Independent control heating zone (excluding furnace temperature control, two inlet, two detectors, two auxiliary heating areas) | |
Maximum operating temperature in auxiliary heating zone | 300ºC |
Detector | |
Hydrogen Flame ionization detector FID | |
Maximum operating temperature | 450ºC |
Minimum check out limit | ≤2.5pgC/s [n-C16] |
Dynamic linear Range | ≥107(±10%) |
Data acquisition Frequency | 100Hz (MAX) |
Thermal conductivity Pool Tester TCD | |
Maximum operating temperature | 400ºC |
Minimum check out limit | <400pg C3H8/ml(He) |
Dynamic linear Range | 105(±5%) |
Data acquisition Frequency | 100Hz (MAX) |
Flame Photometric Detector FPD | |
Maximum operating temperature | 250ºC |
Minimum check out limit | <4pgC/sec,<1pg P/sec |
Dynamic linear Range | >103S,>104P |
Selective | <4pgC/sec,<1pg P/sec |
Electronic Capture Detector ECD | |
Maximum operating temperature | 400ºC |
Detector compensation Gas Type | 5% Methane/Argon or nitrogen |
Minimum check out limit | <0.01Ppg/s lindane |
Dynamic linear Range | >5×1055 |
Data acquisition Frequency | 100Hz (MAX) |
Radioactive sources | <12mCi 63Ni |
Nitrogen and Phosphorus detector NPD | |
Maximum operating temperature | 450ºC |
Minimum check out limit | <0.2 pg N/sec,<0.2 pg P/sec |
Dynamic linear Range | 105N,105P |
Minimum check out limit | <0.3pg C/Sec |
The above detectors are suitable for filling column and capillary column | |
Anti-control software | Optional configuration (Automatic injection B6891N) |
The introduction of Haida
Haida products are widely used in paper products, packaging, ink printing, adhesive tapes, bags, footwear, leather products, environment, toys, baby products, hardware, electronic products, plastic products, rubber products and other industries, and are applicable to all scientific research units, quality inspection institutions and academic fields. Our products meet UL, ASTM, JIS, GB,SO, TAPPI, EN, DIN, BS and other domestic and international standards.
Â
Packaging & Shipping:
Simulation Animatronic Customer Triceratops are covered with air bubble film before put them into the wooden case, which not only has good shock absorption, impact resistance, heat sealing and also has the advantages of nontoxic, odorless, moisture corrosion, good transparency etc.
Â
After-service:
If you face any problems in future during testing process we promise we will give you a reply within 48 hours and solution provide within 3 working days. We can offer operation video and English operation muanual. We can provide video-con.
Â
High-End Lab Gas Chromatography Instrument With Automatic Sampler
Description:
The entire new generation of laboratory high-end automatic gas chromatograph gc6891n, the basic international most advanced technology platform and decades of international industry technology application experience, function, reliability and application flexibility, etc. in the industry leader.
Application:
Oil extraction and refining, petrochemical, fine chemicals, food safety, environmental protection, electronic high purity gas industry, research institutes, quality inspection, safety supervision, police forensic and national security and other fields of analysis and detection.
Performance:
1.Inlet flow rate, chromatographic column load flow, detector gas flow, complete EPC control
Micro-channel Air Circuit Integrated Board
All-imported miniature proportional valves and flow/pressure sensors
Automatic temperature compensation ensures accurate flow and pressure control to 0.01Psi
2.Industry-Leading Detector design
All detectors are high-precision electronic flow/pressure control
Fit and fill column and capillary column
Special ceramic treatment of the enlarged plate, in the humid season is always stable
3.Automatic ignition, hydrogen leak automatic protection function, safe and reliable
4.Accurate furnace temperature tracking design
5.Independent Heating small column box
In the multi-column chromatographic system, the temperature of different columns can be set respectively, so as to achieve the best separation effect of each column.
6.Fully Imported Valve configuration system
Up to 8 valves (four-pass valve, six-pass valve, ten-pass valve and liquid injection valve optional); Automatic control, sequence operation;
7.Precise temperature control of the programmed furnace
Furnace internal control accuracy less than 0.01°c
The temperature difference between the internal points is not more than the °c
Rapid heating and cooling, the highest program heating speed: 120ºC/min, balance time 10 seconds, cooling time 300°c~50°c 6 minutes
Absolute control of the temperature accuracy (with the actual temperature difference is less than 0.3C)
8.The convenient realization of gas cutting technology
Multi-dimensional chromatographic function to complete the separation and analysis of complex samples
It can realize the inverse blowing function of chromatographic column to save the analysis time and cycle greatly.
9.Advanced Power Distribution Management shunt
A 3000 watt UPS can provide 10 units of normal power 2250 watts/set of GC stable working power supply automatic Feed
10.Automatic injection
8-bit automatic injection device (optional Agilent 7683/7693 liquid automatic injection)
11.Automatic Online inspection function
Parameter:
(The table parameters for the company Standard Model parameters, we support customer customization parameters)
(The table parameters for the company Standard Model parameters, we support customer customization parameters)
The introduction of Haida
Haida products are widely used in paper products, packaging, ink printing, adhesive tapes, bags, footwear, leather products, environment, toys, baby products, hardware, electronic products, plastic products, rubber products and other industries, and are applicable to all scientific research units, quality inspection institutions and academic fields. Our products meet UL, ASTM, JIS, GB,SO, TAPPI, EN, DIN, BS and other domestic and international standards.
Â
Packaging & Shipping:
Simulation Animatronic Customer Triceratops are covered with air bubble film before put them into the wooden case, which not only has good shock absorption, impact resistance, heat sealing and also has the advantages of nontoxic, odorless, moisture corrosion, good transparency etc.
Â
After-service:
If you face any problems in future during testing process we promise we will give you a reply within 48 hours and solution provide within 3 working days. We can offer operation video and English operation muanual. We can provide video-con.
Â
The entire new generation of laboratory high-end automatic gas chromatograph gc6891n, the basic international most advanced technology platform and decades of international industry technology application experience, function, reliability and application flexibility, etc. in the industry leader.
Application:
Oil extraction and refining, petrochemical, fine chemicals, food safety, environmental protection, electronic high purity gas industry, research institutes, quality inspection, safety supervision, police forensic and national security and other fields of analysis and detection.
Performance:
1.Inlet flow rate, chromatographic column load flow, detector gas flow, complete EPC control
Micro-channel Air Circuit Integrated Board
All-imported miniature proportional valves and flow/pressure sensors
Automatic temperature compensation ensures accurate flow and pressure control to 0.01Psi
2.Industry-Leading Detector design
All detectors are high-precision electronic flow/pressure control
Fit and fill column and capillary column
Special ceramic treatment of the enlarged plate, in the humid season is always stable
3.Automatic ignition, hydrogen leak automatic protection function, safe and reliable
4.Accurate furnace temperature tracking design
5.Independent Heating small column box
In the multi-column chromatographic system, the temperature of different columns can be set respectively, so as to achieve the best separation effect of each column.
6.Fully Imported Valve configuration system
Up to 8 valves (four-pass valve, six-pass valve, ten-pass valve and liquid injection valve optional); Automatic control, sequence operation;
7.Precise temperature control of the programmed furnace
Furnace internal control accuracy less than 0.01°c
The temperature difference between the internal points is not more than the °c
Rapid heating and cooling, the highest program heating speed: 120ºC/min, balance time 10 seconds, cooling time 300°c~50°c 6 minutes
Absolute control of the temperature accuracy (with the actual temperature difference is less than 0.3C)
8.The convenient realization of gas cutting technology
Multi-dimensional chromatographic function to complete the separation and analysis of complex samples
It can realize the inverse blowing function of chromatographic column to save the analysis time and cycle greatly.
9.Advanced Power Distribution Management shunt
A 3000 watt UPS can provide 10 units of normal power 2250 watts/set of GC stable working power supply automatic Feed
10.Automatic injection
8-bit automatic injection device (optional Agilent 7683/7693 liquid automatic injection)
11.Automatic Online inspection function
Parameter:
(The table parameters for the company Standard Model parameters, we support customer customization parameters)
Column temperature Box | |
Furnace Size | 28×30×18cm |
Temperature control Range | higher than room temperature 5ºC~450ºC; Use liquid nitrogen cold well -80ºC~400ºC; use dry ice trap -55ºC~400ºC |
Temperature setting accuracy | 0.1ºC |
Maximum program heating rate | 120ºC/min |
Maximum once method run time | 999.99min |
Maximum class of program heating | 7 class |
Programmed Temperature Rate | 0.1~120ºC/min (increment 0.1 ºC) |
Operation Column loss compensation (dual channel) | |
Heating Zone | |
6 Independent control heating zone (excluding furnace temperature control, two inlet, two detectors, two auxiliary heating areas) | |
Maximum operating temperature in auxiliary heating zone | 300ºC |
Detector | |
Hydrogen Flame ionization detector FID | |
Maximum operating temperature | 450ºC |
Minimum check out limit | ≤2.5pgC/s [n-C16] |
Dynamic linear Range | ≥107(±10%) |
Data acquisition Frequency | 100Hz (MAX) |
Thermal conductivity Pool Tester TCD | |
Maximum operating temperature | 400ºC |
Minimum check out limit | <400pg C3H8/ml(He) |
Dynamic linear Range | 105(±5%) |
Data acquisition Frequency | 100Hz (MAX) |
Flame Photometric Detector FPD | |
Maximum operating temperature | 250ºC |
Minimum check out limit | <4pgC/sec,<1pg P/sec |
Dynamic linear Range | >103S,>104P |
Selective | <4pgC/sec,<1pg P/sec |
Electronic Capture Detector ECD | |
Maximum operating temperature | 400ºC |
Detector compensation Gas Type | 5% Methane/Argon or nitrogen |
Minimum check out limit | <0.01Ppg/s lindane |
Dynamic linear Range | >5×1055 |
Data acquisition Frequency | 100Hz (MAX) |
Radioactive sources | <12mCi 63Ni |
Nitrogen and Phosphorus detector NPD | |
Maximum operating temperature | 450ºC |
Minimum check out limit | <0.2 pg N/sec,<0.2 pg P/sec |
Dynamic linear Range | 105N,105P |
Minimum check out limit | <0.3pg C/Sec |
The above detectors are suitable for filling column and capillary column | |
Anti-control software | Optional configuration (Automatic injection B6891N) |
The introduction of Haida
Haida products are widely used in paper products, packaging, ink printing, adhesive tapes, bags, footwear, leather products, environment, toys, baby products, hardware, electronic products, plastic products, rubber products and other industries, and are applicable to all scientific research units, quality inspection institutions and academic fields. Our products meet UL, ASTM, JIS, GB,SO, TAPPI, EN, DIN, BS and other domestic and international standards.
Â
Packaging & Shipping:
Simulation Animatronic Customer Triceratops are covered with air bubble film before put them into the wooden case, which not only has good shock absorption, impact resistance, heat sealing and also has the advantages of nontoxic, odorless, moisture corrosion, good transparency etc.
Â
After-service:
If you face any problems in future during testing process we promise we will give you a reply within 48 hours and solution provide within 3 working days. We can offer operation video and English operation muanual. We can provide video-con.
Â
Embroidery Machine,Embroidery Machine For Sale,Embroidery Machine Designs,Embroidery Machine Reviews
Weaving Machine,Quilting Machine Co., Ltd. , http://www.nbquiltingmachine.com